Package size
not availableWeight
not availableDownload the Instruction manual
Executive Standards: Executive Standards: American Heart Association (AHA) 2020 International Cardiopulmonary
Resuscitation (CPR) & Emergency Cardiovascular Care (ECC) Guidelines
Features:
★ Wireless connection between simulator and tablet computer.
■ Simulated vital signs:
1) In the initial state, the simulated human's pupils are dilated and the carotid artery has no pulse.
2) During the compression process, the simulated human carotid artery beats passively, and the pulse frequency
is consistent with the compression frequency.
3) After successful rescue, the pupils of the simulator returned to normal, and the carotid artery beat spontaneously.
■ Can perform standard airway opening.
■ Can carry out artificial hand position chest compression and artificial respiration.
■ Three modes of operation: CPR training, simulation assessment and actual combat assessment are available.
1) Method 1: CPR training, within the set time range, you can perform compressions and blows.
2) Method 2: mode assessment, within the set time frame, according to the 2020 international cardiopulmonary
resuscitation standard, the ratio of compression and insufflation is 30:2, and 5 cycles of operation are completed.
3) Method 3: actual combat assessment, within the set time frame, according to the 2020 international
cardiopulmonary resuscitation standard, complete 5 cycles of compression and insufflation at a ratio of 30:2.
■ Simulate the entire first aid process including consciousness judgment, first aid breathing, pulse checking,
checking breathing, and foreign body removal.
★ Grading system: It can automatically grade the students' grades.
CPR Display Features:
■ Electronic monitoring: Electronic monitoring of airway opening and compression parts, displaying correct
and incorrect times of artificial respiration and external compression.
■ Voice prompts: Chinese voice prompts throughout the process, the volume can be adjusted.
■ The barcode shows the blowing volume: the correct blowing volume is 500/600ml-1000ml.
1) When the blowing volume is too low, the bar code is yellow.
2) When the blowing volume is appropriate, the barcode is green.
3) When the blowing volume is too large, the bar code is red.
■ The barcode shows the compression depth, and the correct compression should be more than 5cm.
1) When the pressing depth is too small, the bar code is yellow.
2) When the depth of the compression attempt is appropriate, the barcode is green.
■ Operation time can be set.
★ Power supply: The human body and the controller have built-in high-capacity lithium batteries,
which can be used while charging.
Printer function:
■ Use an external printer to print transcripts.
■ Transcript covers mode of operation, number of compressions and insufflations per cycle, number
of correct/wrong compressions, cause and number of incorrect compressions, correct/wrong and number of
insufflations, cause and number of incorrect insufflations, setting Set time, operation time and performance evaluation.
Standard set configuration:
■ One advanced cardiopulmonary resuscitation simulator;
■ A tablet computer;
■ One luxury hand-pull and push-type human body hard plastic box;
■ One cardiopulmonary resuscitation pad;
■ One box of disposable disinfection mask (50 sheets/box);
■ One replaceable skin;
■ Five interchangeable lung bags;
■ A set of product warranty card, product qualification certificate, instruction manual and first aid operation manual.